PDA-TR-80《制药实验室数据完整性管理体系》(中英文对照版).docx
《PDA-TR-80《制药实验室数据完整性管理体系》(中英文对照版).docx》由会员分享,可在线阅读,更多相关《PDA-TR-80《制药实验室数据完整性管理体系》(中英文对照版).docx(16页珍藏版)》请在课桌文档上搜索。
1、PDATR80制药实验室数据完整性管理体系(中英文对照版)5.0DataIntegrityinthePharmaceuticalMicrobiologyLaboratory5.0微生物实验室的数据完整性5.1GeneralConsiderationsandRisks一般原则及风险Theapproachesusedtoinvestigatetheoccurrenceofsuspecteddataintegrityissuesthathrecentlyourredinapharmaceuticalmicrobiologylaboratorycanbechallengingand,insomecas
2、es,maybeverydifferentthanthoseusedtoevaluatesimilaroccurrencesinananalyticalchemistrylaboratory,Manymicrobiologicalmethodsareperformedmanually;subsequently,therecordedresultsareoftenbasedonthevisualobsen/ationsbyanindividualscientistperformingthetests.制药企业微生物实验室对可疑数据完整性问题的调查方法,越来越成为个挑战,并且在一些情况下,与同样发
3、生可疑数据的化学分析实验室的调查方法完全不同。很多微生物测试方法都是手动操作,以及所有的测试结果都由微生物测试人员人工检查并记录。Listedbelowareafewexamplesofregulatoryobservations,WarningLetters,orotherinstitutionalaccountsthatnotedataintegrityproblemsassociatedwithmicrobiologicallaboratoryrecords.Theseareonlyexamplesandarenotintendedtobeanall-inclusivelistofcon
4、cerns:以下是一些官方检查项,警告信,或其他官方检查关于微生物实验室记录数据完整性问题的情况列举,这些仅是举例并不完全代表所有与微生物实验室数据完整性相关的问题:Companyfailedtorecordandreportreliableandaccuratedatafortheenvironmentalmonitoring(EM)results;forexample,contaminationinGradeAroomswererecordedandreportedashavingnoviablemicroorganismspresentwhen,infact,microbialconta
5、minationwaspresent.Specifically,thesettleagarplatesusedintheseareaswerefelselyreportedashavingnocoloniespresentbutwerefoundtocontain16colony-formingunits(CFU),morethancouldbereasonablyoverlooked.公司未记录和报告真实准确的环境监测结果数据:例如,A级区实际存在微生物污染但实际记录和报告为零。特别是A级区沉降菌报告为1无菌落生长”,但实际上发现沉降菌结果为16cfu,可能会有更多类似的情况被掩盖。Comp
6、anyfailedtoimplementanadequatequalityassurancesystemasevidencedby:productsterilitytestfailuresthatoccurredandwerenotreported,investigated,ordocumented;fivebatchesofviralharveststhatwererejectedduetocontamination,yetnoreportswereinitiated;andacompanypracticethatproductsterilitytestfailre(s)wereinvest
7、igatedonlyifmorethanonetestjarperbatchofthefirstorsecondharvestsfailedforsterility.公司质量保证体系未有效执行,具体表现为:产品无菌测试失败未报告,调查或记录:5批次产品由于病毒污染而被拒绝放行,但没有任何调查报告被发起,以及某些公司仅在第二次无菌失败或同一批次超过瓶出现无菌样品失败的情况下,才会发起无菌调查Companyusedacontractlaboratorytoperformmicrobiologicaltesting;however,thecompanyauditchecklistusedtoeval
8、uatethesuitabilityofthislaboratorywascompletedbythecontractlaboratory,notthecompany,withnofollow-upverification.公司存在委托实验室进行微生物检测的情况,然而,对委托实验室符合性审计的主体是由该委托实验室进行而非公司,且并未进行任何确认。Privatetestinglaboratoryclaimedtohaveconductedmicrobiologicaltesting,yetitdidnothavethelaboratoryequipment(i.e.,incubators)and
9、/ormedianecessarytoperformtheanalysis.公司声称内部进行微生物实验测试,但实验室并没有实验相关的设备(如培养箱)和/或测试所必须使用的培养基。Companyusedanunofficia,notebooktorecordmicrobialcontaminationintheplantswatersystem;however,therewasnoofficialinvestigationordocumentationregardingthewatersystemcontaminationwithaknownpathogen(Pseudomonasaerugin
10、osa).Comment:Thistypeofobservationrelatestoboththemicrobiologylaboratoryandoperatorsbehaviors.Periodically,deceptiveindividualswillusethesametechniquetomislead,misrepresent,and/orobscureemergingmicrobialproblemsinmanufacturingequipmentthatcanimpactproductquality.公司使用“非正式”的记录本以记录工厂内水系统的微生物污染情况:然而,当发现
11、水系统中存在已知控制菌(铜绿假单胞菌)污染时,公司并未针对此污染情况发起任何正式的调查或记录。CompanyrecordedresultsthatthegrowthpromotiontestonthemediausedforsimulationstudiessupportedgrowthmeetingthestandardsetbyUSPChapterSterilityTestswhen,infact,themicroorganismsdidnotgrow(30).Inanothercase,filamentousfungiwereseengrowinginallfivespikedmedia
12、tubes,indicatingcontamination,yetlaboratoryrecordsclaimedthatallfivedistinctspeciesofmicroorganismswereactuallygrowingpertheUSPstandard.公司记录用于培养基模拟灌装的培养基促生长测试结果符合USP无菌检测章节的标准菌种生长要求,然而事实上,XX(30)微生物并未生长。另一个情形中检查人员发现,真菌菌丝在5管液体培养基试管中生长,显示了污染,但实验室记录却显示按照USP标准5管试验管中显示各测试菌种生长良好。Again,whilethislistisnotexha
13、ustive,itdoespresentactualinspectionobservationsmadebyseveralregulatoryauditorsduringtheirdocumentationofdataintegrityanomaliesinpharmaceuticalmicrobiologylaboratories.虽然以上显示的清单并不详尽,但却来源于多次官方审计检查中微生物实验室存在的缺陷检查记录清单。5.1.1 InterviewingAnalysts问询分析人员Onecriticalelementinconductinganauditfordataintegrityp
14、roblemsinamicrobiologicallaboratoryisinterviewingtheindividualswhoperformtheQA/QCtests,inparticular,thelaboratoryanalystsortechnicians.WhenreviewinganalyticalresultsrecondedonworksheetsordataprintoutsfromtheLIMS1forexample,itisextremelydifficulttodetectdatathatshouldhavebeenrecordedbutwasnot.Muchofw
15、hatanalystslearncomesfromon-the-jobtraining,yetunofficialdialoguewithcowokersorsupervisorsisrarelycapturedordocumented.Forinstance,whenasenioranalystinstructsajunioranalystonhowtohandletheappearanceofunwantedmicroorganismsfoundgrowingonanalyticalpetriplates(suchaswritethenumericalcountofthesuspected
16、coloniesonthelidofthepetridishbutdontrecorditontheofficialworksheetuntilthesupervisorhasachancetoreviewit),thisunofficia,practicewillnotbefoundinthecompany,sstandardoperatingprocedures(SOPs).Anauditorcanbestassessthepotentialforinappropriatepractices,first,byverifyingtheacceptancecriteriadescribedin
17、SOPsand,then,byinquiringoftheanalystsortechniciansiftheyhavebeeninstructedtoadjustormodifydataordivertfromthelaboratorySOPsinanyform.Withoutconductingsuchfoce-to-faceinterviews,thiskindofmicrobiologicaldatamanipulationwouldbeextremelydifficulttodetect.对微生物实验室数据完整性问题的审计一项重要的基本要素是问询执行微生物测试的QA/QC人员,特别是
18、实验室的分析师和技术人员。当审核记录于工作表或从LlMS系统中打印的分析结果时,很难发现本应被记录而未被记录的数据。大部分分析人员的知识来源于在岗培训,因此同事间的或与主管间的非正式谈话就很难被捕捉或记录。例如,当一个高级技术员指导新员工进行培养皿微生物计数,当发现培养皿上不好的(或非预期生长的)微生物时(例如,在主管审核结果之前将计数结果写在培养皿上而不是记录表格中),这种“非正式的操作就不会出现在公司SoP描述中。审核员可以评估潜在不当做法的最佳方式是,确认SoP中描述的验收标准,然后,通过询问分析员或技术人员,去分析他们是否被指示调整或修改数据或以任何形式从实验室SoP转移。如果不进行这
19、种面对面的面谈,这种微生物数据操纵将极其难以察觉。如果没有面对面的这种沟通,这种类型的微生物实验室数据操作将很难被发现。5.1.2 On-siteLaboratoryandSamplingReview公司内实验室和取样环节审核Thereareseveralproceduralstepswhenhandling,shipping*andstoringmicrobiologicalsamplesthatcandramaticallyandnegativelyimpactfinalanalyticalresults.Specificexamplesofmanagingsamplesthatcandi
20、minishrecoveryofmicrobiologicalorendotoxinresultsand,thus,shouldbeavoidedthroughproceduresandadequateemployeetraining,arelistedbelow:文件中有很多关于微生物样品取样,运输,储存的步骤会对最终微生物测试结果存在显著的、不良的影响。为避免影响微生物及内毒素测试结果应当包括完善的管理文件和足够的人员培训,例子包括:Collectingin-processproductorwatersamplesinaninappropriatecontainerthatmaybind(
21、orremove)abacterialendotoxinfromthesamplemaylaterreducethetruelevelofbacterialendotoxinswithinthattestportion.使用不合适的容器取中间产品样品或水的样品可能会弱化(或去除)样品中的细菌内毒素水平,随后可能减少被测试样品中真正的内毒素水平。 Theexcessiveuseofdisinfectantstospraythesamplingport(s)priortotakingthesamplemayresultinthedisinfectantdrippingintothesamplebo
22、ttleandreducingtheactualbioburdenoftheproductsample.Samplingfromthesampleportsshouldcloselysimulatethecommonpracticesperformedduringroutineproductionoperations.取样前对取样口使用消毒剂过度喷洒可能导致消毒剂滴落在取样瓶中导致降低所取样品中真正的微生物负载水平。从取样口取样应当正常模拟日常生产时使用该取样点的情况。 Whenusingin-linesamplecollectionmanifoldsforcollectingintermed
23、iate-stageproductmanufacturing,themanifoldneedstocooldownafterheatsterilizationsoitdoesnotkillthemicrobescollectedforlaboratorytesting.采用在线样品收集管道抽取中间体产品时,收集管道在加热灭菌后需要冷却,以免杀死供实验室检测用样品中收集到的微生物。 ProductsamplecollectionbagsshouldnotbehelddirectlyunderaUVlightwithinastoragecabinet.ExposuretoUVlightwillki
24、llthemicrobespresentbeforethesamplecollectionbagsaredeliveredtothelaboratoryfortesting.取样瓶不应该直接放在有UV紫外灯的传递窗中。样品瓶传递至实验室之前暴露在UV紫外灯下将杀灭取样器中的微生物 Microbiologicalsamplebagsshouldnotbestoredinafreezerorextremelycoldrefrigerator,whichmayinjureorstressindigenousmicrobes.Microbialsamplesshouldbeplacedwithinac