1、TECO F33Variable Speed DriveInstruction manual EnglishSoftware version 4.2XTECOTECO F33INSTRUCTION MANUAL - ENGLISHSoftWare version 4.2xDocument number: 01-4428-01Edition: r2Date of release: 10-06-2009 Copyright TECO 2005 - 2009TECO retains the right to change specifications and illustrations in the
2、 text, without prior notification. The contents of this document may not be copied without the explicit permission of TECO.Instruction manualRead this instruction manual before using the Variable Speed Drive, VSD.Handlingthe variable speed driveInstallation, commissioning, demounting, taking measure
3、ments, etc, of or on the variable speed drive may only be carried out by personnel technically qualified for the task. The installation must be carried out in accordance with local standards.Openingthe variable speed driveAwaRNING: Always switch off the mains voltage before opening the variable spee
4、d drive and wait at least 5 minutes to allow the buffer capacitors to discharge.Always take adequate precautions before opening the variable speed drive. Although the connections for the control signals and the switches are isolated from the main voltage, do not touch the control board when the vari
5、able speed drive is switched on.Precautions to be taken with a connected motorIf work must be carried out on a connected motor or on the driven machine, the mains voltage must always be disconnected from the variable speed drive first. Wait at least 5 minutes before starting work.EarthingThe variabl
6、e speed drive must always be earthed via the mains safety earth connection.Earth leakage currentThis variable speed drive has an earth leakage current which does exceed 3.5 mA AC. Therefore the minimum size ofthe protective earth conductor must comply with the local safety regulations for high leaka
7、ge current equipment which means that according the standard IEC61800-5-l the protective earth connection must be assured by one of following conditions:1. Use a protective conductor with a cable cross-section of at least 10 mm2 for copper (Cu) or 16 mm2 for aluminium (Al).2. Use an additional PE wi
8、re, with the same cable cross-section as the used original PE and mains supply wiring.Residual current device (RCD) compatibilityThis product cause a DC current in the protective conductor. Where a residual current device (RCD) is used for protection in case of direct or indirect contact, only a Typ
9、e B RCD is allowed on the supply side of this product. Use RCD of 300 mA minimum.EMC RegulationsIn order to comply with the EMC Directive, it is absolutely necessary to follow the installation instructions. All installation descriptions in this manual follow the EMC Directive.Mains voltage selection
10、The variable speed drive may be ordered for use with the mains voltage range listed below.JNFX4048: 230-480 VJNFX5052: 440-525 VJNFX69: 500-690 VVoltage tests (Megger)Do not carry out voltage tests (Megger) on the motor, before all the motor cables have been disconnected from the variable speed driv
11、e.CondensationIf the variable speed drive is moved from a cold (storage) room to a room where it will be installed, condensation can occur. This can result in sensitive components becoming damp. Do not connect the mains voltage until all visible dampness has evaporated.Incorrect connectionThe variab
12、le speed drive is not protected against incorrect connection of the mains voltage, and in particular against connection of the mains voltage to the motor outlets U, V and W. The variable speed drive can be damaged in this way.Power factor capacitors for improvingCOSRemove all capacitors from the mot
13、or and the motor outlet.Precautions during AutoresetWhen the automatic reset is active, the motor will restart automatically provided that the cause ofthe triphas been removed. If necessary take the appropriate precautions.TransportTo avoid damage, keep the variable speed drive in its original packa
14、ging during transport. This packaging is specially designed to absorb shocks during transport.IT Mains supplyThe variable speed drives can be modified for an IT mains supply, (non-earthed neutral), please contact your supplier for details.Heat warningBe aware of specific parts on the VSD having high
15、 temperature.DC-Iink residual voltageaWARNING: After switching off the mainsf supply, dangerous voltage can still b /4 PrMeirtlntheVSDaWhenopeningtheVSD for Installing and/or Commlsslonliig activities watt at least 6 mlnrtM. In case of malfunction a qualified technician houM check the IXMInk or wait
16、 for one hour before dlsmantilng the VSD for repair.SaMy Instructions.laIlrtl,OCUCti(l aMa1.11 2Delivery and unpackingUsing of th instruction manual551.3Type code number51.4Standards61.4.1Product standard for EMC61.5 Dismantling and scrapping71.5.1 Disposal of old electrical and electronic equipment
17、. 71.6 Glossary81.6.1 Abbreviations and symbols81.6.2 Definitions82.1 Utting instructions92.2 Stand-alone units102.2.1 Cooling102.2.2 Mounting schemes112.3 Cabinet mounting132.3.1 Cooling132.3.2 Mounting schemes133Iiistallfltioii (153.1 Before installation153.2 Cable connections for 0003 to 0073153.
18、2.1 Mains cables153.2.2 Motor cables163.3 Connect motor and mains cables for 0090 to 1500.183.4 Cable specifications193.5 Stripping lengths193.5.1 Dimension of cables and fuses193.5.2 Tightening torque for mains and motor cables193.6 Thermal protection on the motor203.7 Motors in parallel204. Contro
19、l Connections214.1 Control board214.2 Terminal connections224.3 Inputs configurationwith the switches224.4 Connection example234.5 Connecting the Control Signals244.5.1 Cables244.5.2 Types of control signals254.5.3 Screening254.5.4 Single-ended or double-ended connection?254.5.5 Current signals (0)4
20、-20 mA)264.5.6 Twisted cables264.6 Connecting options26GOtting StflrtOd B*NMaaBMiMMaaMaaaM 275.1 Connect the mains and motor cables275.1.1 Mains cables275.1.2 Motor cables275.2 Using the function keys275.3 Remote control285.3.1 Connect control cables285.3.2 Switch on the mains285.3.3 Set the Motor D
21、ata285.3.4 RuntheVSD285.4 Local control295.4.1 Switch on the mains295.4.2 Select manual control295.4.3 Set the Motor Data295.4.4 Enter a Reference Value295.4.5 Run the VSD296. Appl Icotioiis3 工6.1 Application overview316.1.1 Pumps316.1.2 Fans316.1.3 Compressors326.1.4 Blowers327Rflaln FOatUres7.1 Pa
22、rameter sets337.1.1 One motor and one parameter set347.1.2 One motor and two parameter sets347.1.3 Two motors and two parameter sets347.1.4 Autoreset at trip347.1.5 Reference priority347.1.6 Preset references357.2 Remote control functions357.3 Performing an Identification Run377.4 Using the Control