1、word1 / 71 1目的目的/PURPOSE/PURPOSE由于产品的本身属性,培养基产品PPM= pre-poured media 对生产的洁净度要求需要控制在 ISO7 的环境下进展,因此该方案定义了如何在 PPM 生产动态情况下进展环境监测,其中包括浮游菌, 沉降菌和接触试验的取样方法,取样点和取样频率。RevisionhistoryRevisionhistory: :ReleaseRelease 1.0:1.0: Initial ReleaseReleaseRelease 1.1:1.1: 1. .Add the number of maximum participants in
2、room in the record 2.Add the identification of mold and spore in the recordNameName FunctionFunctionSignatureSignature andand DateDateAuthorAuthorKnight WANGQuality ControlJay SUNValidation EngineerHong WEIQC SupervisorReviewer(s)Reviewer(s)Jackie PENGProduction ManagerApproverApproverYinzi DIAOQA &
3、 QC Managerword2 / 7As a result of the product itself attributes, PPM product need ISO 7 requirements for production. The protocol defines how to monitor the environment in a PPM production dynamic environment, including samples method, samples point and samples frequency of floating bacteria, settl
4、ing bacteria and contact experiments 2 2X X 围围/SCOPE/SCOPE该方案仅可以适用于梅里埃某某生物制品某某培养基产品PPM的生产区域,其位于某某梅里埃的生产楼一楼。This protocol is applicable to the PPM Production area in BSB only, which is located on the first floor of production building in BSB3 3职责职责/RESPONSIBILITIES/RESPONSIBILITIES4 4实验方案实验方案/EXPERIM
5、ENTS/EXPERIMENTS PROTOCOLPROTOCOL4.14.1浮游菌检测浮游菌检测/floating/floating bacteriabacteria testtest4.1.1取样 Sampling1. 采样器进入被测房间前先用消毒房间的消毒剂灭菌,然后在紫外传递窗进入罐装间。Sampler should be clean with disinfectant from sterilization disinfection room first before entering the room, and then it should be entered to UV wind
6、ows.2. 用消毒剂擦净培养皿的外外表。Clean the plate of outside surface with disinfectant3. 采样前,先用消毒剂清洗采样器的顶盖,转盘以与罩子的内外面,采样完毕,再用消毒剂轻轻喷射罩子的内壁和转盘。Clean the cap, turntable and cover of sampler with disinfectant before and after sampled4. 采样口使用前必须高温灭菌。如用消毒剂对采样口的外壁与内壁进展消毒时,应将其残留液倒掉并晾干。Cover of Sampler should be high tem
7、perature sterilization. If the inside and outside wall is disinfected, it should be dried5. 采样者应穿戴与被测洁净区域相应的工作服,在操作前,双手用消毒剂消毒并戴无菌手套操作。部门部门/Dept/Dept职责职责/RESPONSIBILITIES/RESPONSIBILITIESQC 团队/QC team准备动态环境取样方案, 培训生产操作员取样方法完成动态环境监测的孵育和读数记录完成动态环境监测的趋势分析和报告Preparing the protocol, training the Productio
8、n operator to collect the samplesPerforming the sample incubation and recordplete the dynamic environment of trend analysis and report生产团队/Production team完成动态环境的取样Performing the sample collection in the dynamic environmentword3 / 7Sampler should worn corresponding work clothes in the clean area. Han
9、ds should be disinfected with disinfectant and wear sterile gloves before used the sampler6. 采样仪器经消毒后先不放入培养皿,开启浮游菌采样器,使仪器中的剩余消毒剂蒸发,时间不少于 5 分钟,并检查流量根据采样量调整设定采样时间。The sampler should be open without plate more than 5 minutes in order to evaporate residual disinfectant and check the sampling time and sa
10、mpling amount.7. 关闭浮游菌采样器,放入 NUT 或 COS 或 TSA3P 培养皿,盖上盖子。Turn off the sampler and put the NUT or COS and TSA3P and replace the cap8. 置采样口于采样点后,开启浮游菌采样器进展采样。Turn on the sampler to start sampling in the sampling point9. 在整个实验过程中拿取培养基时都应用手指捏着培养皿以确保培养基不受污染。In the whole test process, when taking plates sh
11、ould to fingers hold dish ensure medium from pollution.10.最小采样量 Minimum sample quantity洁净度级别 Cleanliness Class采样量 L/次 Sample Quantity L/times10010001000050010000010030000010011.每个采样点一般采样一次.One sampling in every sample point generally.4.1.2培养 Incubation1. 全部采样完毕后,将培养皿倒置于恒温培养箱中培养At the end of the samp
12、ling, inversed the plates in the incubator to incubate2. 30-35 度培养箱中培养,时间不少于 2 天Incubating the plates in the 30-35 incubator and more than 2 days3. 每批培养基应有对照实验,检验培养根本身是否污染。 Every batch of plates should be reference in order to check the quality of plates itself 4.1.3菌落计数 Bacteria counting1. 用肉眼对培养皿上
13、所有的菌落直接计数,标记或在菌落计器上点计。Count directly all the colonies on petri dishes with the eye or count in the colony meter2. 假如平板上有 2 个或 2 个以上的菌落重叠,可分辨时仍以 2 个或 2 个以上菌落计数If two or more than two colonies overlap on the plate, count them into the number if possible to recognize。3. 菌落计数时确认霉菌和芽孢数量(如有)Identify the m
14、old and spore number when counting the colony (If needs)word4 / 74.24.2接触实验检测接触实验检测 ContactContact ExperimentExperiment TestTest4.2.1取样 Sampling用 COS 或 NUT 或 CT3P 平板接触将要离开罐装间的操作员口罩,肘,手套,鞋套和写字台*,直接接触采样点持续 10 秒留下痕迹,取样完毕后盖上皿盖。在整个实验过程中拿取培养基时都应用手指捏着培养皿以确保培养基不受污染。Contacting to the operators gloves, elbow,
15、 mask, shoes and desk* with COS or NUT or CT3P about 10 seconds and pressureleave a trace.The operator will be left the filling roomHolding the plates in order to protect the plates from pollution in the process.4.2.2培养 Incubation1. 全部采样完毕后,将培养皿倒置于恒温培养箱中培养。At the end of the sampling, inversed the pl
16、ates in the incubator to incubate2. 在 30-35 度培养箱中培养,时间不少于 2 天。Incubating the plates in the 30-35 incubator and more than 2 days3. 每批培养基应有对照实验,检验培养根本身是否污染。Every batch of plates should be reference in order to check the quality of plates itself 4.2.3菌落计数 Bacteria counting1. 用肉眼对培养皿上所有的菌落直接计数,标记或在菌落计器上